Multimeters

Digital Multimeter


M200

M300

POCKET SIZE DMM, ONE HAND ROTATION

  • Low cost, ideal for DIY users
  • 3 1/2 digits LCD with a max. reading of 1999
  • Meet with IEC1010 & UL1244 safety requirements
  • Side attachable test leads
  • Overload protection
  • DCV: 2-20-200-500V, +/- 0.5%
  • ACV: 200-500V, +/- 1.2%
  • DCA: 200mA, +/- 1.5%
  • OHM: 2k-20k-200k-2MW, +/- 1.0%
  • Audible continuity & Diode test
  • Dimensions: 70 x 120 x 18mm
  • Battery: 12VX1, GP23A
  • Packing: in gift box or blister

M320

M320

AUTO-RANGING DMM, ONE HAND ROTATION

  • 3 3/4 digits LCD with a max. reading of 3999
  • Meet with IEC1010 & UL 1244 safety requirements
  • Auto ranging on all functions
  • Side attachable test leads
  • Overload protection
  • Auto power-off
  • DCV: 4-40-400-600V, +/- 0.5%
  • ACV: 4-40-400-600V, +/- 1.0%
  • DCA: 40-400mA, +/- 2.0%
  • ACA: 40-400mA, +/- 3.0%
  • OHM: 400-4k-40k-400k-4M-40MW, +/- 1.5%
  • Audible continuity & Diode test
  • Dimensions: 70 x 120 x 18mm
  • Battery: 3VX1, SR44
  • Packing: in gift box or blister

M92, M92A

M92, M92A

GENERAL PURPOSE DMM

  • 3 1/2 digits LCD with a max. reading of 1999
  • Low battery indication
  • Overload protection
  • DCV: 200m-2-20-200-1000V, +/- 0.5%
  • ACV: 2-20-200-750V, +/- 0.8%
  • DCA: 2m-20m-200m-20A, +/- 0.8% (M92)
              200u-2m-20m-200m-20A, +/- 0.8% (M92A)
  • ACA: 2m-20m-200m-20A, +/- 0.8%
  • OHM: 200-2k-20k-200k-2M-20MW, +/- 0.8%
  • BATT: 1.5-9V 9 (M92 only)
  • Audible continuity & Diode test
  • Transistor test (M92A only)
  • Dimensions: 85 x 165 x 32mm
  • Color: Dark gray, Yellow
  • Accessories: Yellow holster
  • Battery: Popular 9Vx1

M93, M93A

NOTEBOOK SUPER SLIM DMM

  • Easily fits in shirt pocket
  • Low battery indication
  • Overload protection


M93 / M93A

  • DCV: 2-20-200-400V, +/- 0.5%
  • ACV: 200-400V, +/- 1.2%
  • DCA: 200m, +/- 1.5%
  • OHM: 2k-20k-200k-2MW, +/- 0.8%
  • Audible continuity (M93A only)
  • Dimensions: 57 x 108 x 12.5mm
  • Battery: 9Vx1, GP10A
  • Packing: in gift box or blister
OA-4097

OA-4097

  • DCV: 200mV +/- (0.25% of rdg + 2 digits)
              2/20/200/1000V +/- (0.5% of rdg + 2 digits)
  • ACV: 200/750V +/- (1.2% of rdg + 10 digits)
              45Hz ~ 450Hz
  • DCA: 200u/2/20mA +/- (1% of rdg + 2 digits)
              200mA +/- (1.2% of rdg + 2 digits)
              10A +/- (2% of rdg + 2 digits)
  • OHM: 200/2k/20k/200kW +/- (0.8% of rdg + 2 digits)
               2MW +/- (1% of rdg + 2 digits)
  • Diode Test - Test current 15mA MAX
  • Power source: 6F22(9V) X 1
  • Size weight: 126 x 70 x 24mm, 170g
OA-4098

OA-4098

  • DCV: 200mV +/- (0.3% of rdg + 2 digits)
              2/20/200/1000V +/- (0.5% of rdg + 2 digits)
  • ACV: 200/750V +/- (1.2% of rdg + 5 digits)
  • DCA: 200u/2m/20mA/200mA +/- (1% of rdg + 2 digits)
              10A +/- (1.2% of rdg + 2 digits)
  • OHM: 200W +/- (1.0% of rdg + 3 digits)
               2/20/200kW +/- (0.8% of rdg + 2 digits)
               2MW +/- (1.5% of rdg + 2 digits)
  • hFE: 0 ~ 1000
  • BATT: 1.5/9V +/- (3% of rdg + 2 digits)
  • Continuity checking with a buzzer
  • Diode Test - Test current 1mA +/- 0.5mA
         Open Circuit Voltage approx 2.8V
  • Power source: 6F22(9V) X 1
  • Size weight: 128 x 72 x 333mm, 200g (including battery)
OA-4099

OA-4099

PEN-TYPE AUTO-RANGING DMM WITH LOGIC FUNCTION

  • 3 1/2 digits LCD with a Max. reading of 1999
  • Easily operatedwith one hand
  • Built-in TTL and CMOS logic tester
  • Data hold, auto ranging
  • Auto polarity indication
  • Audible continuity & diode test
  • Overload protection
  • DCV: 200m-2-20-200-500V, +/- 0.5%
  • ACV: 2-20-200-500V, +/- 0.8%
  • DCA: 200m, +/- 1.5%
  • ACA: 200m, +/- 2.5%
  • OHM: 200-2k-20k-200k-2M-20MW, +/- 0.8%
  • Audible continuity: <1000W
  • Logic tester: H>3.5V, L<1.5V
  • Dimensions: 31 x 185 x 22mm
  • Battery: 1.5V x 2, SR44


Analog Multimeter

MF-133

MF-133

  • 5 Functions 16 Measuring Ranges
  • 2000 ohms/volt DC/AC Sensitivity
  • Single knob function Switch
  • Safety teat leads & instruction
  • Use one "AA" (1.5V) battery
  • DCV: 2.5/10/50/250/500V (2kW/V) +/- 5%f.s.
  • ACV: 10/50/250/500V (2kW/V) +/- 5%f.s.
  • DCA: 500u/10m/250mA +/- W/V) +/- 5%f.s.
  • OHM: 2k/200kWMAX +/- 5% of arc.
  • Battery Test: 1.5V/9V
  • Size , Weight: 100 x 64 x 35mm, 95g
MF-213

MF-213

  • Easy to read 3 color scale
  • Recessed safety designed input terminals
  • Mirrored scale reduces errors due to parallax
  • Ideal for testing electrical and electronic circuits
  • Ideal for shop, office,, home, boat, car and farm
  • DCV: 10/50/250/1000V +/- 5%f.s.
  • ACV: 10/50/250/1000V +/- 5%f.s.
  • DCA: 0.5/50/250mA +/- 5%f.s.
  • OHM: 10k/1MW +/- 5% of arc.
  • dB: 20 ~ 62 dB
  • Power Source: R6(1.5V) x 1
  • Size , Weight: 90 x 60 x 32mm, 90g
OA-4049

OA-4049

  • Excellent DC resoultion factor of 2mV and expanded resistance measurement from 0.2W to 20MW
  • Series capacitor terminal (OUTPUT) blocks DC to enable measurement of only AC components
  • Continuity checking with a buzzer
  • A large and bright meter with a scale length of 80mm and its sensitivity of 44uA at full scale
  • Fuse and diode protection
  • Measures hFE to 1000 using optional TR connector
  • DCV: 100m/500m/2.5/10/50/250/1000V (20kW/V) +/- 3%f.s. 25kV (with HVV probe)
  • ACV: 10/50/250/1000V (9kW/V) +/- 4%f.s.
  • DCA: 50u/2.5m/25m/250mA +/- 3%f.s.
  • OHM: 2k/20k/200k/2M/20MW MAX +/- 3% of arc.
  • dB: 10 ~ 62 dB
  • LI: 150 u/1.5m/15m/150mA
  • hFE: 0 ~ 1000 (W/TR connector)
  • Power Source: R6(1.5V) x 2, 6F22(9V) x 1
  • Size , Weight: 150 x 100 x 36mm, 280g
OA-4049A

OA-4049A

  • Excellent DC resoultion factor of 2mV and expanded resistance measurement from 0.2W to 20MW
  • Series capacitor terminal (OUTPUT) blocks DC to enable measurement of only AC components
  • A large and bright meter with a scale length of 80mm and its sensitivity of 44uA at full scale
  • Fuse and diode protection
  • Measures hFE to 1000 using optional TR connector
  • DCV: 100m/500m/2.5/10/50/250/1000V (20kW/V) +/- 3%f.s. 25kV (with HVV probe)
  • ACV: 10/50/250/1000V (9kW/V) +/- 4%f.s.
  • DCA: 50u/2.5m/25m/250mA +/- 3%f.s.
  • OHM: 2k/20k/200k/2M/20MW MAX +/- 3% of arc.
  • dB: 10 ~ 62 dB
  • L1: 150u/1.5m/15m/150mA
  • hFE: 0 ~ 1000 (W/TR connector)
  • Power Source: R6(1.5V) x 2, 6F22(9V) x 1
  • Size , Weight: 150 x 100 x 36mm, 280g
YX-360TRD

YX-360TRD

  • This instrument is portable multitester designated for measurement of weak current circuits
  • Panel face protectioncover which serves also as a stand is employed
  • Our technology has made it possible to measure high resistance (up to maximum 200MW) with low voltage
  • Band meter of drop shock type with high sensitivity has been employed
  • Overload protection circuit up to maximum 230V is provided
  • DCV: 100m/250m/2.5/10/50/250V +/- 3%f.s.
              1000 +/- 5%f.s.
  • ACV: 10/50/250V +/- 4%f.s.
              1000V +/- 5%f.s.
  • DCA: 50u/2.5m/25m/250mA +/- 3%f.s.
  • OHM: 2k/20k/200k/2MW +/- 3% of arc.
               200MW +/- 5% of arc.
  • dB: 10 ~ 62 dB
  • L1: 1.5u/150u/15m/150mA
  • hFE: 0 ~ 1000
  • Power Source: R6(1.5V) x 2
  • Size , Weight: 160 x 128 x 41mm, 320g

[ Home] [Wires & Cables] [Speakers] [Plugs & Jacks] [Gold Plated Plugs]
[Rechargeable Batteries] [Multimeters] [Power Supplies] [Soldering Irons]

Power Supplies


AC/DC Adaptor

OA-4069 110/220V AC/DC ADAPTOR 300mA
OA-4070 110/220V AC/DC ADAPTOR 500mA
OA-4071 110/220V AC/DC ADAPTOR 1000mA

13.8V DC Regulated Power Supplies

MODEL:OA-4081
OUTPUT:3A
SURGE CURRENT5A
SOURCE REGULATION::1.5%
LOAD REGULATION:1.5%
RIPPLE VOLTAGE<15mV (RMS)
PROTECTION MODE:SHORT CIRCUIT
SIZE:144 x 100 x 205mm
WEIGHT:2.2Kg
MODEL:OA-4082
OUTPUT:3A
SURGE CURRENT8A
SOURCE REGULATION::1.5%
LOAD REGULATION:1.5%
RIPPLE VOLTAGE<25mV (RMS)
PROTECTION MODE:SHORT CIRCUIT
SIZE:144 x 100 x 230mm
WEIGHT:3.1Kg
MODEL:OA-4083
OUTPUT:7A
SURGE CURRENT9A
SOURCE REGULATION::1.5%
LOAD REGULATION:1.5%
RIPPLE VOLTAGE<35mV (RMS)
PROTECTION MODE:SHORT CIRCUIT
SIZE:144 x 100 x 230mm
WEIGHT:4.7Kg
MODEL:OA-4084
OUTPUT:10A
SURGE CURRENT12A
SOURCE REGULATION::1.5%
LOAD REGULATION:1.5%
RIPPLE VOLTAGE<40mV (RMS)
PROTECTION MODE:SHORT CIRCUIT
SIZE:200 x 150 x 280mm
WEIGHT:5.3Kg
MODEL:OA-4085
OUTPUT:15A
SURGE CURRENT17A
SOURCE REGULATION::1.5%
LOAD REGULATION:1.5%
RIPPLE VOLTAGE<60mV (RMS)
PROTECTION MODE:SHORT CIRCUIT
SIZE:200 x 122 x 280mm
WEIGHT:8.7Kg
MODEL:OA-4086
OUTPUT:20A
SURGE CURRENT25A
SOURCE REGULATION::1.5%
LOAD REGULATION:1.5%
RIPPLE VOLTAGE<60mV (RMS)
PROTECTION MODE:SHORT CIRCUIT
SIZE:200 x 150 x 320mm
WEIGHT:8.9Kg

DC/AC Inverter

Model:OA-4093A
OUTPUT WAVE:SQUARE
OUTPUT POWER:150W
PROTECTION:OUTPUT OVERLOAD PROTECTION, INPUT OVERVOLTAGE AND UNDERVOLTAGE PROTECTION
WARNING MODE:SOUND WARNING
SIZE:112 x 45 x 155mm
WEIGHT:0.9Kg
MODEL:OA-4094A
OUTPUT WAVE:SQUARE
OUTPUT POWER:200W
PROTECTION:OUTPUT OVERLOAD PROTECTION
 
 
 
WARNING MODE:SOUND WARNING
SIZE:200 x 120 x 235mm
WEIGHT:5Kg
MODEL:OA-4095
OUTPUT WAVE:SQUARE
OUTPUT POWER:400W
PROTECTION:OUTPUT OVERLOAD PROTECTION
WARNING MODE:SOUND WARNING
SIZE:236 x 120 x 246mm
WEIGHT:0.9Kg
MODEL:OA-4108N
OUTPUT WAVE:SQUARE
OUTPUT POWER:1000W
PROTECTION:OUTPUT OVERLOAD PROTECTION
WARNING MODE:SOUND WARNING
SIZE:300 x 150 x 280mm
WEIGHT:17.5Kg
MODEL:OA-4109
INVERTER WITH CHARGER
OUTPUT WAVE:SQUARE
OUTPUT POWER:550W
PROTECTION:OUTPUT OVERLOAD PROTECTION
WARNING MODE:SOUND WARNING
CHARGING CURRENT10A
SIZE:235 x 125 x 300mm
WEIGHT:12Kg
MODEL:OA-4110
INVERTER WITH CHARGER
OUTPUT WAVE:SQUARE
OUTPUT POWER:1200W
PROTECTION:OUTPUT OVERLOAD PROTECTION
WARNING MODE:SOUND WARNING
CHARGING CURRENT20A
SIZE:300 x 160 x 340mm
WEIGHT:19Kg